@ -1595,6 +1595,19 @@ ControlObjectClient_getObjectReference(ControlObjectClient self);
|
|
|
|
|
ControlModel
|
|
|
|
|
ControlObjectClient_getControlModel(ControlObjectClient self);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Get the type of ctlVal.
|
|
|
|
|
*
|
|
|
|
|
* This type is required for the ctlVal parameter of the \ref ControlObjectClient_operate
|
|
|
|
|
* and \ref ControlObjectClient_selectWithValue functions.
|
|
|
|
|
*
|
|
|
|
|
* \param self the control object instance to use
|
|
|
|
|
*
|
|
|
|
|
* \return MmsType required for the ctlVal value.
|
|
|
|
|
*/
|
|
|
|
|
MmsType
|
|
|
|
|
ControlObjectClient_getCtlValType(ControlObjectClient self);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Send an operate command to the server
|
|
|
|
|
*
|
|
|
|
@ -1607,12 +1620,25 @@ ControlObjectClient_getControlModel(ControlObjectClient self);
|
|
|
|
|
bool
|
|
|
|
|
ControlObjectClient_operate(ControlObjectClient self, MmsValue* ctlVal, uint64_t operTime);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Send a select command to the server
|
|
|
|
|
*
|
|
|
|
|
* The select command is only used for the control model "select-before-operate with normal security"
|
|
|
|
|
* (CONTROL_MODEL_SBO_NORMAL). The select command has to be sent before the operate command can be used.
|
|
|
|
|
*
|
|
|
|
|
* \param self the control object instance to use
|
|
|
|
|
*
|
|
|
|
|
* \return true if operation has been successful, false otherwise.
|
|
|
|
|
*/
|
|
|
|
|
bool
|
|
|
|
|
ControlObjectClient_select(ControlObjectClient self);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Send an select with value command to the server
|
|
|
|
|
*
|
|
|
|
|
* The select-with-value command is only used for the control model "select-before-operate with enhanced security"
|
|
|
|
|
* (CONTROL_MODEL_SBO_ENHANCED). The select-with-value command has to be sent before the operate command can be used.
|
|
|
|
|
*
|
|
|
|
|
* \param self the control object instance to use
|
|
|
|
|
* \param ctlVal the control value (for APC the value may be either AnalogueValue (MMS_STRUCT) or MMS_FLOAT/MMS_INTEGER
|
|
|
|
|
*
|
|
|
|
@ -1621,6 +1647,16 @@ ControlObjectClient_select(ControlObjectClient self);
|
|
|
|
|
bool
|
|
|
|
|
ControlObjectClient_selectWithValue(ControlObjectClient self, MmsValue* ctlVal);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Send a cancel command to the server
|
|
|
|
|
*
|
|
|
|
|
* The cancel command can be used to stop an ongoing operation (when the server and application
|
|
|
|
|
* support this) and to cancel a former select command.
|
|
|
|
|
*
|
|
|
|
|
* \param self the control object instance to use
|
|
|
|
|
*
|
|
|
|
|
* \return true if operation has been successful, false otherwise.
|
|
|
|
|
*/
|
|
|
|
|
bool
|
|
|
|
|
ControlObjectClient_cancel(ControlObjectClient self);
|
|
|
|
|
|
|
|
|
@ -1630,9 +1666,25 @@ ControlObjectClient_setLastApplError(ControlObjectClient self, LastApplError las
|
|
|
|
|
LastApplError
|
|
|
|
|
ControlObjectClient_getLastApplError(ControlObjectClient self);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Send commands in test mode.
|
|
|
|
|
*
|
|
|
|
|
* When the server supports test mode the commands that are sent with the test flag set
|
|
|
|
|
* are not executed (will have no effect on the attached physical process).
|
|
|
|
|
*
|
|
|
|
|
* \param self the control object instance to use
|
|
|
|
|
* \param value value if the test flag (true = test mode).
|
|
|
|
|
*/
|
|
|
|
|
void
|
|
|
|
|
ControlObjectClient_setTestMode(ControlObjectClient self, bool value);
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* \brief Set the origin parameter for control commands
|
|
|
|
|
*
|
|
|
|
|
* The origin parameter is used to identify the client/application that sent a control
|
|
|
|
|
* command. It is intended for later analysis.
|
|
|
|
|
*
|
|
|
|
|
*/
|
|
|
|
|
void
|
|
|
|
|
ControlObjectClient_setOrigin(ControlObjectClient self, const char* orIdent, int orCat);
|
|
|
|
|
|
|
|
|
|