- fixed - potential race condition when using IedConnection_installReportHandler and IedConnection_uninstallReportHandler

pull/462/merge
Michael Zillgith 2 years ago
parent d6c53b1569
commit cdd0684ffb

@ -3,7 +3,7 @@
*
* Client implementation for IEC 61850 reporting.
*
* Copyright 2013-2022 Michael Zillgith
* Copyright 2013-2024 Michael Zillgith
*
* This file is part of libIEC61850.
*
@ -283,14 +283,27 @@ lookupReportHandler(IedConnection self, const char* rcbReference)
return NULL;
}
static void
uninstallReportHandler(IedConnection self, const char* rcbReference)
{
ClientReport report = lookupReportHandler(self, rcbReference);
if (report != NULL) {
LinkedList_remove(self->enabledReports, report);
ClientReport_destroy(report);
}
}
void
IedConnection_installReportHandler(IedConnection self, const char* rcbReference, const char* rptId, ReportCallbackFunction handler,
void* handlerParameter)
{
Semaphore_wait(self->reportHandlerMutex);
ClientReport report = lookupReportHandler(self, rcbReference);
if (report != NULL) {
IedConnection_uninstallReportHandler(self, rcbReference);
uninstallReportHandler(self, rcbReference);
if (DEBUG_IED_CLIENT)
printf("DEBUG_IED_CLIENT: Removed existing report callback handler for %s\n", rcbReference);
@ -306,8 +319,8 @@ IedConnection_installReportHandler(IedConnection self, const char* rcbReference,
else
report->rptId = NULL;
Semaphore_wait(self->reportHandlerMutex);
LinkedList_add(self->enabledReports, report);
Semaphore_post(self->reportHandlerMutex);
if (DEBUG_IED_CLIENT)
@ -319,12 +332,7 @@ IedConnection_uninstallReportHandler(IedConnection self, const char* rcbReferenc
{
Semaphore_wait(self->reportHandlerMutex);
ClientReport report = lookupReportHandler(self, rcbReference);
if (report != NULL) {
LinkedList_remove(self->enabledReports, report);
ClientReport_destroy(report);
}
uninstallReportHandler(self, rcbReference);
Semaphore_post(self->reportHandlerMutex);
}
@ -367,6 +375,8 @@ IedConnection_triggerGIReport(IedConnection self, IedClientError* error, const c
void
iedConnection_handleReport(IedConnection self, MmsValue* value)
{
Semaphore_wait(self->reportHandlerMutex);
MmsValue* rptIdValue = MmsValue_getElement(value, 0);
if ((rptIdValue == NULL) || (MmsValue_getType(rptIdValue) != MMS_VISIBLE_STRING)) {
@ -770,14 +780,13 @@ iedConnection_handleReport(IedConnection self, MmsValue* value)
}
}
Semaphore_wait(self->reportHandlerMutex);
if (matchingReport->callback != NULL)
matchingReport->callback(matchingReport->callbackParameter, matchingReport);
exit_function:
Semaphore_post(self->reportHandlerMutex);
exit_function:
return;
}

@ -1,7 +1,7 @@
/*
* iec61850_client.h
*
* Copyright 2013-2021 Michael Zillgith
* Copyright 2013-2023 Michael Zillgith
*
* This file is part of libIEC61850.
*
@ -1256,9 +1256,11 @@ typedef void (*ReportCallbackFunction) (void* parameter, ClientReport report);
* Otherwise the internal data structures storing the received data set values will not be updated
* correctly.
*
* When replacing a report handler you only have to call this function. There is no separate call to
* \note Replacing a report handler you only have to call this function. There is no separate call to
* IedConnection_uninstallReportHandler() required.
*
* \note Do not call this function inside of the ReportCallbackFunction. Doing so will cause a deadlock.
*
* \param self the connection object
* \param rcbReference object reference of the report control block
* \param rptId a string that identifies the report. If the rptId is not available then the
@ -1273,6 +1275,8 @@ IedConnection_installReportHandler(IedConnection self, const char* rcbReference,
/**
* \brief uninstall a report handler function for the specified report control block (RCB)
*
* \note Do not call this function inside of the ReportCallbackFunction. Doing so will cause a deadlock.
*
* \param self the connection object
* \param rcbReference object reference of the report control block
*/