Commit Graph

316 Commits (40b8f992012604b18efca3a38656b20398e7b314)

Author SHA1 Message Date
Michael Zillgith 7185c3b8d4 - IED server: add support for SMV control blocks ("SMVC") in config file
parser
4 years ago
Michael Zillgith de3aba0cb6 - .NET API: added support for server integrated GOOSE publisher
- IED server: fixed bug in GoCBEventHandler
4 years ago
Michael Zillgith 1bb76893a2 - fixed compilation problem when compiling without GOOSE support (#325) 4 years ago
Michael Zillgith 1a09b9548a - IED server: control handling - fixed problem in test flag handling 4 years ago
Michael Zillgith 1b2d194694 - IED server: For SBOes check test flag match when accepting operate (sSBOes8) 4 years ago
Michael Zillgith f866132e84 - IED server: Reject Cancel/SBOw in WaitForChange state - fixed problem with test case sCtl26 4 years ago
Michael Zillgith 9e6e3487da - removed compiler warnings 4 years ago
Michael Zillgith cb3f460fcf - .NET API: added functions to access DataAttribute properties 4 years ago
Michael Zillgith 3532623319 - IED server: Goose publisher - set NdsCom when data set not configured or GoEna fails because of large data set 4 years ago
Michael Zillgith c4dcd37449 - added new function DataAttribute_setValue 5 years ago
Michael Zillgith 2b1104c0d3 - IED server - control model - send AddCause with operate- for DOes, SBOes control models 5 years ago
Michael Zillgith bd4bd0fab6 - IED server: GoCB has invalid data set reference when datSet="" in SCL file 5 years ago
Michael Zillgith 4e15343f5b - IED server: integrated GOOSE publisher - lock data model during GOOSE retransmission to avoid corrupted GOOSE data 5 years ago
Michael Zillgith ea268b46a7 - IED server: make presence of RCB.Owner configurable at runtime with function IedServerConfig_enableOwnerForRCB (B1502/S1634) 5 years ago
Michael Zillgith fd3847dcc5 - IED server: make presence of BRCB.ResvTms configurable at runtime with function IedServerConfig_enableResvTmsForBRCB (F1558) 5 years ago
Michael Zillgith dc22dc76ec - IED server: fixed bug in log service - old-entry and old-entry-time not updated 5 years ago
Michael Zillgith 842bc271cd - IED server: added new function IedServer_handleWriteAccessForComplexAttribute. Changed WriteAccessHandler behavior when ACCESS_POLICY_ALLOW. 5 years ago
Michael Zillgith cc905b5013 - IED server/model: Added additional functions for ModelNode access 5 years ago
Michael Zillgith 60d66e5ba4 - some code beautification 5 years ago
Michael Zillgith 5afa1310f3 - IED server: Add function ModelNode_getObjectReferenceEx 5 years ago
Michael Zillgith 5e39c94cf3 - IED server: allow IedServer_setServerIdentity with some parameters set to NULL 5 years ago
Michael Zillgith fe39cc9b24 - IED server: control models - fixed bug that only one control is unselected when connection closes 5 years ago
Michael Zillgith 4f0667b597 - removed some warnings and code cleanup 5 years ago
Michael Zillgith db1671587e - IED server: fixed bug - logs (journals) are added to all logical devices instead of just the parents 5 years ago
Michael Zillgith 9e064ab709 - IED Server: prevent integrated GOOSE publisher to crash when ethernet socket cannot be created 5 years ago
Michael Zillgith 23a3b3a371 - IED server: make compatible with tissue 1178 5 years ago
Michael Zillgith 6c2b9ad473 - IED server: reporting - implemented behavior according to tissue 1432 5 years ago
Michael Zillgith 74a227bdf2 - IED server: WriteAccessHandler can tell the stack not to update the
value when returning DATA_ACCESS_ERROR_SUCCESS_NO_UPDATE
5 years ago
Michael Zillgith 5f2e14f712 Merge branch 'v1.5' of https://github.com/mz-automation/libiec61850 into v1.5 5 years ago
Michael Zillgith 945fe080f3 - removed some compiler warnings 5 years ago
Michael Zillgith d08f5a67ac - IED server: fixed problem with client connection handling of setting groups 5 years ago
Michael Zillgith 474a482766 IED server: fixed problem with CONFIG_IEC61850_RCB_ALLOW_ONLY_PRECONFIGURED_CLIENT configuration option enabled 5 years ago
Michael Zillgith 40f8b76ad7 - IED server: handle BRCB.Owner correctly when client uses pre-assigned RCB instance 5 years ago
Michael Zillgith 4793e298ff - IED server: fixed problem that BL FC is not writable (#287) 5 years ago
Michael Zillgith 4deca9a4c0 - IED server: fixed potential deadlock in report module when service tracking is enabled 5 years ago
Michael Zillgith 7b671f3a01 - GOOSE subscriber: accept GOOSE messages with the correct maximum size of DatSet and GoID 5 years ago
Michael Zillgith b88c4216c8 - IED server: send AddCause for invalid origin also in case of direct control models 5 years ago
Michael Zillgith 0c9d1b16f8 - fixed struct initialization problem with Visual Studio 5 years ago
Michael Zillgith 8a55ef47bf - IED server: ControlPerformCheckHandler has same parameters when called again in state WAITING_FOR_SELECT 5 years ago
Michael Zillgith 14f4f1ccf0 - IED server: added ControlSelectStateChangedHandler callback for control model 5 years ago
Michael Zillgith fb5ed11001 - IED server: also respect user provided error and addCause from ControlPerformCheckHandler when the handler is called multiple times in waiting-for-select state 5 years ago
Michael Zillgith a5bcd3c251 - IED server: fixed problem - control not unselected after connection is closed for sboClass "operate-many" 5 years ago
Michael Zillgith 9348683462 - IED server: fixed bug in cdc.c (wrong type for tOpOk data attribute) 5 years ago
Michael Zillgith cc80bffa69 - IED server: support for configuration of EditSG service and online visibility of SGCB.ResvTms at runtime 5 years ago
Michael Zillgith 53d8a2f715 - IED server: changed types TrkOps and OptFlds to variable length bit strings 5 years ago
Michael Zillgith 23da9ba28e - IED server: control service tracking - fixed problem with missing attributes for SBOw tracking 5 years ago
Michael Zillgith 767bc887de - IED server: fixed problems in control service tracking 5 years ago
Michael Zillgith 49cc901263 - fixed problem in control service tracking 5 years ago
Michael Zillgith 3f42387ed7 - IED server: fixed dupd trigger handling 5 years ago
Michael Zillgith e4fcb923a0 - fixed problems in control service tracking 5 years ago