Mikael Bourhis
6e8053a1eb
Examples: add command line parameter for choosing the MMS port in some server examples
...
Some 'server' examples already have this capability.
Complete the 'server' example list that support the possibility of using
another MMS port than the default one (port '102').
Signed-off-by: Mikael Bourhis <mikael.bourhis@smile.fr>
3 years ago
Michael Zillgith
ad78b9de26
- removed redundant declarations (LIB61850-359)
3 years ago
Michael Zillgith
7099535a39
Merge branch 'v1.5_develop' into v1.6_develop
3 years ago
Michael Zillgith
b27681f408
- implemented GET_PARAMETER event for IedServer_RCBEventHandler
...
- implemented additional access functions for ReportControlBlock to allow access to runtime values
4 years ago
Michael Zillgith
9a2fd3e23e
- started to implement functional naming for LDs
4 years ago
Michael Zillgith
98e7c5816a
- code formatting; compiler warnings
5 years ago
Romain Naour
dcbd9f94ab
examples/server_example_basic_io
...
There is an access error while using iec61850_client_example1 with server_example_basic_io.
From [1]:
/* write a variable to the server */
value = MmsValue_newVisibleString("libiec61850.com");
IedConnection_writeObject(con, &error, "simpleIOGenericIO/GGIO1.NamPlt.vendor", IEC61850_FC_DC, value);
The error code is IED_ERROR_ACCESS_DENIED = 21.
By default access to variables with FC=DC and FC=CF is not allowed, fix this
by changing the access policy as suggested by [2].
[1] https://github.com/mz-automation/libiec61850/blob/v1.4.2.1/examples/iec61850_client_example1/client_example1.c#L71
[2] https://libiec61850.com/libiec61850/documentation/iec-61850-client-tutorial/#comment-61994
Signed-off-by: Romain Naour <romain.naour@smile.fr>
5 years ago
Michael Zillgith
a6bad96d25
- fixed examples that have control handlers with old signature
5 years ago
Michael Zillgith
09b23aaa74
- IEC 618580 server: Added function IedServer_setServerIdentity to set values for MMS identity service
6 years ago
Michael Zillgith
0dff4286aa
- merged latest changes to the server reporting module from 1.3 branch
...
- merged with 1.3 branch
7 years ago
Michael Zillgith
5ef3acc3e6
- added error handling in iec61850_client_example4
7 years ago
Michael Zillgith
51c29fe9a7
- IEC 61850 server/ MMS server: maximum number of client connections configurable at runtime
7 years ago
Michael Zillgith
26af0d93c2
- IEC 61850 server: made IEC 61850 edition configurable at runtime
7 years ago
Michael Zillgith
71493036dc
- IEC 61850 server/MMS server: make dynamic data set service configurable at runtime with IedServerConfig object (new functions IedServerConfig_enableLogService and IedServerConfig_isLogServiceEnabled)
7 years ago
Michael Zillgith
0a3d86601b
- IEC 61850 server/MMS server: make dynamic data set service configurable at runtime with IedServerConfig object (new functions IedServerConfig_enableDynamicDataSetService and IedServerConfig_isDynamicDataSetServiceEnabled)
7 years ago
Michael Zillgith
27e883a1bc
- MMS server: fixed bug in association service (file rename was not reported as supported service)
7 years ago
Michael Zillgith
77c4d3ae03
- 9-2LE example: updated data set
7 years ago
Michael Zillgith
c28d06f4d8
- IEC 61850 server: added support to set file service base path with server configuration object
7 years ago
Michael Zillgith
7cb5ff670a
- IEC 61850 server: added support to configure report buffer at runtime
...
- IEC 61850 server: new IedServerConfig type and new IedServer constructor
7 years ago
Michael Zillgith
9a8415b3e6
- IEC 61850 server: prevent sending reports when data model is locked (updated)
7 years ago
Michael Zillgith
34dff85ed6
- added missing examples
8 years ago