Michael Zillgith
|
9f8d52005b
|
- MMS client: fixed problem when reusing connection
|
7 years ago |
Michael Zillgith
|
0dff4286aa
|
- merged latest changes to the server reporting module from 1.3 branch
- merged with 1.3 branch
|
7 years ago |
Michael Zillgith
|
952f12bffb
|
- mms-utility: added read array
|
7 years ago |
Michael Zillgith
|
452abd7dbf
|
- MMS client/server: added support for component alternate access for generic variable read requests
|
7 years ago |
Michael Zillgith
|
1c461009c2
|
- MMS client/server: fixed potential memory leaks in TLS handling code
|
7 years ago |
Michael Zillgith
|
5e35e6694b
|
- added new example folder
|
7 years ago |
Michael Zillgith
|
b6c9a56d4a
|
- .NET API: added more async functions
- .NET API: added GetFileDirectoryEx function
. file-tool: add "s" option to send only a single get file directory request
|
7 years ago |
Michael Zillgith
|
e252715aa9
|
- added report subscription activation to non-thread mode client example
|
7 years ago |
Michael Zillgith
|
4157c9c5da
|
- extended server_example_control to show how to change ctlModel with online service
|
7 years ago |
Michael Zillgith
|
3b577fbf3a
|
- file-tool: added option to show sub directory content
|
7 years ago |
Michael Zillgith
|
0c006f2892
|
- improved error handling in iec61850_9_2_LE_example
|
7 years ago |
Michael Zillgith
|
afab66cb4d
|
- error handling in SV publisher example
|
7 years ago |
Michael Zillgith
|
388337a60d
|
- IEC 61850 client: added support for non-thread mode (IedConnection_createEx, IedConnection_tick)
- added example for non-thread mode client and asynchronous API
|
7 years ago |
Michael Zillgith
|
d0f4c06d62
|
- IEC 61850 client: added functions IedConnection_getLogicalDeviceVariables, IedConnection_getLogicalDeviceDataSets, and IedConnection_getLogicalDeviceDataSetsAsync to address #89
|
7 years ago |
Michael Zillgith
|
a817b3d3c6
|
- updated data model of server_example_basic_io
- common: MmsVariableSpecification_getChildValue now also accepts "." as separator
|
7 years ago |
Michael Zillgith
|
43e0fb4d05
|
- IEC 61850 Client: ControlObjectClient - added async control actions
|
7 years ago |
Michael Zillgith
|
1cc350ed4a
|
- IEC 61850 client: implemented IedConnection_writeDataSetValuesAsync
|
7 years ago |
Michael Zillgith
|
c04b4e928d
|
- IEC 61850 client: implemented IedConnection_readDataSetValuesAsync
|
7 years ago |
Michael Zillgith
|
5ef3acc3e6
|
- added error handling in iec61850_client_example4
|
7 years ago |
Michael Zillgith
|
1eaf43ac8b
|
- SV: fixed RefrTm and SmpSynch handling in SV publisher
|
7 years ago |
Michael Zillgith
|
e90d5d44fa
|
- IEC 61850 client: added async discovery functions
|
7 years ago |
Michael Zillgith
|
44d8ad8d15
|
- IEC 61850/MMS client: changed all invokeId parameters in async callbacks to uint32_t
|
7 years ago |
Michael Zillgith
|
54d8fb74d7
|
- IEC 61850 client: added async versions for connect, abort, release, get variable specification, write object
|
7 years ago |
Michael Zillgith
|
7767e282d6
|
- MMS client: added asynchronous get name list functions
|
7 years ago |
Michael Zillgith
|
fc1d62d1a7
|
MMS client: added asynchronous read journal service
|
7 years ago |
Michael Zillgith
|
2f0211b188
|
- GOOSE publisher example: fixed memory leak
|
7 years ago |
Michael Zillgith
|
c0ce64c758
|
- file-tool: file client example is now compatible with windows
|
7 years ago |
Michael Zillgith
|
77f97dc006
|
- replaced strndup
|
7 years ago |
Michael Zillgith
|
51c29fe9a7
|
- IEC 61850 server/ MMS server: maximum number of client connections configurable at runtime
|
7 years ago |
Michael Zillgith
|
2585aab516
|
- cleanup examples makefiles
- fixed bug in MMS mapping read handler
|
7 years ago |
Michael Zillgith
|
d0061fce96
|
- updated ICD file for server_example_complex_array
- added client example for array handling
|
7 years ago |
Michael Zillgith
|
26af0d93c2
|
- IEC 61850 server: made IEC 61850 edition configurable at runtime
|
7 years ago |
Michael Zillgith
|
14c8434201
|
- server_example_basic_io: fixed ICD/CID file
|
7 years ago |
Michael Zillgith
|
020b1f40aa
|
- IEC 61850 server: integrated automatic handling of "origin" and "ctlVal" status (ST) values for controllable CDCs
|
7 years ago |
Michael Zillgith
|
58b4d6c107
|
-IEC 61850 server: added ReadAccessHandler to control read access
|
7 years ago |
Michael Zillgith
|
71493036dc
|
- IEC 61850 server/MMS server: make dynamic data set service configurable at runtime with IedServerConfig object (new functions IedServerConfig_enableLogService and IedServerConfig_isLogServiceEnabled)
|
7 years ago |
Michael Zillgith
|
0a3d86601b
|
- IEC 61850 server/MMS server: make dynamic data set service configurable at runtime with IedServerConfig object (new functions IedServerConfig_enableDynamicDataSetService and IedServerConfig_isDynamicDataSetServiceEnabled)
|
7 years ago |
Michael Zillgith
|
27e883a1bc
|
- MMS server: fixed bug in association service (file rename was not reported as supported service)
|
7 years ago |
Michael Zillgith
|
c36050f455
|
- renamed iec61850_client_example3 to iec61850_client_example_control
- removed outcommented code
|
7 years ago |
Michael Zillgith
|
b5cb80868c
|
- IED SERVER: fixed bug when calling write access handler (when access policy DENY)
|
7 years ago |
Michael Zillgith
|
eacdfa953d
|
- IED SERVER: fixed bug when calling write access handler (wrong pointer for ClientConnection object)
|
7 years ago |
Michael Zillgith
|
47d34702b1
|
- updated IEC 61850-9-2 LE example to be more realistic
|
7 years ago |
Michael Zillgith
|
2e160d6279
|
- added server side example for the substitution service
|
7 years ago |
Michael Zillgith
|
77c4d3ae03
|
- 9-2LE example: updated data set
|
7 years ago |
Michael Zillgith
|
894ea2e726
|
- SV: added function SVPublisher_ASDU_setSmpCntWrap
- added quality flag "derived"
- updated 9-2LE publisher example
|
7 years ago |
Michael Zillgith
|
c28d06f4d8
|
- IEC 61850 server: added support to set file service base path with server configuration object
|
7 years ago |
Michael Zillgith
|
7cb5ff670a
|
- IEC 61850 server: added support to configure report buffer at runtime
- IEC 61850 server: new IedServerConfig type and new IedServer constructor
|
7 years ago |
Michael Zillgith
|
9a8415b3e6
|
- IEC 61850 server: prevent sending reports when data model is locked (updated)
|
7 years ago |
Michael Zillgith
|
d327f0715e
|
- added function SVReceiver_enableDestAddrCheck
|
7 years ago |
Michael Zillgith
|
d45e729ecf
|
- MMS client/server: added missing length field checks to increase decoder stability
|
8 years ago |