Michael Zillgith
|
e252715aa9
|
- added report subscription activation to non-thread mode client example
|
7 years ago |
Michael Zillgith
|
4157c9c5da
|
- extended server_example_control to show how to change ctlModel with online service
|
7 years ago |
Michael Zillgith
|
bbb56a16a3
|
- removed some compiler warnings
|
7 years ago |
Michael Zillgith
|
1d61afaa8b
|
- C library: removed C++ style line comments
|
7 years ago |
Michael Zillgith
|
388337a60d
|
- IEC 61850 client: added support for non-thread mode (IedConnection_createEx, IedConnection_tick)
- added example for non-thread mode client and asynchronous API
|
7 years ago |
Michael Zillgith
|
5ed474a44a
|
- MMS client: fixed problem with async connect timeout
|
7 years ago |
Michael Zillgith
|
ef076efe9f
|
- IEC 61850 client: fixed problem with connection state handling
|
7 years ago |
Michael Zillgith
|
3e30910319
|
- IEC 61850 client: added missing async functions for files
|
7 years ago |
Michael Zillgith
|
0842097b7e
|
- IEC 61850 server: fixed some small bugs and compiler warnings
- IEC 61850 server: retrun object-access-unsupported when ctlModel is status-only
|
7 years ago |
Michael Zillgith
|
618a84d37c
|
- IEC 61850 client: add public header for function ControlObjectClient_createEx to create a client control object without the need to request information from the server
|
7 years ago |
Michael Zillgith
|
91c22b3193
|
- IEC 61850 server: added IedServer_updateCtlModel function to change control model at runtime
|
7 years ago |
Michael Zillgith
|
cad88b67a1
|
- IEC 61850 client: fixed bug in new control object client implmentation - missing free for oper variable specification
|
7 years ago |
Michael Zillgith
|
89d623866e
|
- IEC 61850 client: add function IedConnection_getFileAsync
|
7 years ago |
Michael Zillgith
|
f78f338b49
|
- IEC 61850 client: added implementations for functions IedConnection_getLogicalDeviceVariables, IedConnection_getLogicalDeviceDataSets, and IedConnection_getLogicalDeviceDataSetsAsync to address #89
|
7 years ago |
Michael Zillgith
|
d0f4c06d62
|
- IEC 61850 client: added functions IedConnection_getLogicalDeviceVariables, IedConnection_getLogicalDeviceDataSets, and IedConnection_getLogicalDeviceDataSetsAsync to address #89
|
7 years ago |
Michael Zillgith
|
2c5fb89449
|
- IEC 61850 client: implemented tissue 1178 client side (select-response+ is non-NULL)
|
7 years ago |
Michael Zillgith
|
46211a01e7
|
- IEC 61850 client: IedConnection - added CONNECTING AND CLOSING states - removed IDLE state (now only CLOSED)
|
7 years ago |
Michael Zillgith
|
e12113acde
|
- IEC 61850 client: implemented IedConnection_installStateChangedHandler
|
7 years ago |
Michael Zillgith
|
43e0fb4d05
|
- IEC 61850 Client: ControlObjectClient - added async control actions
|
7 years ago |
Michael Zillgith
|
1cc350ed4a
|
- IEC 61850 client: implemented IedConnection_writeDataSetValuesAsync
|
7 years ago |
Michael Zillgith
|
c04b4e928d
|
- IEC 61850 client: implemented IedConnection_readDataSetValuesAsync
|
7 years ago |
Michael Zillgith
|
f644b8d777
|
- IEC 61850 client: ControlObjectClient - avoid crash when "ctlVal" is not present in "Oper", also accept "setMag" instead of "ctlVal".
|
7 years ago |
Michael Zillgith
|
c9fe177a87
|
- IEC 61850 server: fixed potential deadlock in report processing
|
7 years ago |
Michael Zillgith
|
836892849c
|
- IEC 61850 client: improved support for segmented report handling
|
7 years ago |
Michael Zillgith
|
e90d5d44fa
|
- IEC 61850 client: added async discovery functions
|
7 years ago |
Michael Zillgith
|
44d8ad8d15
|
- IEC 61850/MMS client: changed all invokeId parameters in async callbacks to uint32_t
|
7 years ago |
Michael Zillgith
|
7ec38e9615
|
- IEC 61850 client: added async client side RCB handling
|
7 years ago |
Michael Zillgith
|
2b7dc5c5fe
|
- added API export/internal decorations
- removed .def files for windows
|
7 years ago |
Michael Zillgith
|
5201473262
|
- IEC 61850 client: added more prototypes for async client API
|
7 years ago |
Michael Zillgith
|
e6884d721b
|
- IEC 61850 client: added asynchronous query log functions
|
7 years ago |
Michael Zillgith
|
54d8fb74d7
|
- IEC 61850 client: added async versions for connect, abort, release, get variable specification, write object
|
7 years ago |
Michael Zillgith
|
56d7ee4f0b
|
- IEC 61850/MMS client: Add support for write variable for array element with component
- added lost README file for winpcap
|
7 years ago |
Michael Zillgith
|
70c1cd691d
|
- MMS client: refactoring for async connect, abort, release
|
7 years ago |
Michael Zillgith
|
aa86d3b259
|
- IEC 61850 server: number of dynamic data sets configurable at runtime
|
7 years ago |
Michael Zillgith
|
a0adcf94e7
|
- IEC 61850 Server: made number of data set entries configurable at runtime
|
7 years ago |
Michael Zillgith
|
a830fc3cfb
|
- IEC 61850 server: reporting - don't delete pending events when buffered report is enabled and dataset didn't change
|
7 years ago |
Michael Zillgith
|
51c29fe9a7
|
- IEC 61850 server/ MMS server: maximum number of client connections configurable at runtime
|
7 years ago |
Michael Zillgith
|
e980a519ae
|
- IEC 61850 server: control objects - fixed bug in select response for SBO control model
|
7 years ago |
Michael Zillgith
|
2585aab516
|
- cleanup examples makefiles
- fixed bug in MMS mapping read handler
|
7 years ago |
Michael Zillgith
|
8b957b8f82
|
- IEC 61850 client: add support for single array element access (with component specification)
|
7 years ago |
Michael Zillgith
|
26af0d93c2
|
- IEC 61850 server: made IEC 61850 edition configurable at runtime
|
7 years ago |
Michael Zillgith
|
6199da1e55
|
- IEC 61850 server: CONFIG_REPORTING_SUPPORTS_OWNER replaced by CONFIG_IEC61850_EDITION_1
|
7 years ago |
Michael Zillgith
|
e7905cc16b
|
- IEC 61850 server: memory handling optimization in control module
|
7 years ago |
Michael Zillgith
|
020b1f40aa
|
- IEC 61850 server: integrated automatic handling of "origin" and "ctlVal" status (ST) values for controllable CDCs
|
7 years ago |
Michael Zillgith
|
713ca54cd0
|
- IEC 61850 server: optimized dynamic memory management in control handling; memory will be initialized at server start
|
7 years ago |
Michael Zillgith
|
6618093f7a
|
- IEC 61850 server: functions IedModel_getModelNodeByShortObjectReference and IedModel_getModelNodeByObjectReference now also work with object references that have only LD part
|
7 years ago |
Michael Zillgith
|
58b4d6c107
|
-IEC 61850 server: added ReadAccessHandler to control read access
|
7 years ago |
Michael Zillgith
|
0b51d6841a
|
- added Socket_activateTcpKeepAlive function
|
7 years ago |
Michael Zillgith
|
9995a7cfc4
|
- IEC 61850 client: fixed bug in select response handling
|
7 years ago |
Michael Zillgith
|
71493036dc
|
- IEC 61850 server/MMS server: make dynamic data set service configurable at runtime with IedServerConfig object (new functions IedServerConfig_enableLogService and IedServerConfig_isLogServiceEnabled)
|
7 years ago |