#include <chrono>
|
||
|
#include <iostream>
|
||
|
#include <memory>
|
||
|
#include <sstream>
|
||
|
#include "includes.h"
|
||
|
#include <spdlog/fmt/ostr.h>
|
||
|
|
||
|
// Uncomment below to see timing calculations printed to stdout
|
||
|
//#define PERF_LOG_MACRO_PRINT_DURATIONS
|
||
|
|
||
|
struct MyObj
|
||
|
{
|
||
|
MyObj()
|
||
|
: val(0)
|
||
|
, a_long_string("AAAAAAAAAAAAAAAAAAAAAAAAAABBBBBBBBBBBBBBBBBBBBBBBBCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC")
|
||
|
, stream_run(false)
|
||
|
{}
|
||
|
int val;
|
||
|
std::string a_long_string;
|
||
|
mutable bool stream_run;
|
||
|
};
|
||
|
std::ostream& operator<<(std::ostream& os, const MyObj& c)
|
||
|
{
|
||
|
c.stream_run = true;
|
||
|
return os << c.a_long_string << " a " << c.val;
|
||
|
}
|
||
|
|
||
|
TEST_CASE("PERF log macro does not run the ostream", "[PERF_log_macro]")
|
||
|
{
|
||
|
MyObj obj;
|
||
|
auto null_sink = std::make_shared<spdlog::sinks::null_sink_st>();
|
||
|
auto logger = std::make_shared<spdlog::logger>("null_logger", null_sink);
|
||
|
logger->set_level(spdlog::level::info);
|
||
|
SPDLOG_PERF_TRACE(logger, "another obj, {}", obj);
|
||
|
logger->set_level(spdlog::level::trace);
|
||
|
CHECK(!obj.stream_run);
|
||
|
SPDLOG_PERF_TRACE(logger, "another obj, {}", obj);
|
||
|
CHECK(obj.stream_run);
|
||
|
}
|
||
|
|
||
|
TEST_CASE("performace test when writing suing macro", "[PERF_log_macro]")
|
||
|
{
|
||
|
{
|
||
|
MyObj obj;
|
||
|
auto null_sink = std::make_shared<spdlog::sinks::null_sink_st>();
|
||
|
auto logger = std::make_shared<spdlog::logger>("null_logger", null_sink);
|
||
|
logger->set_level(spdlog::level::info);
|
||
|
|
||
|
std::size_t loop_count = 1000;
|
||
|
auto begin = std::chrono::high_resolution_clock::now();
|
||
|
for (size_t i = 0; i < loop_count; i++)
|
||
|
{
|
||
|
SPDLOG_PERF_INFO(logger, "custom class with operator<<: {}..", obj);
|
||
|
}
|
||
|
auto end = std::chrono::high_resolution_clock::now();
|
||
|
auto dur = end - begin;
|
||
|
auto seconds = std::chrono::duration_cast<std::chrono::microseconds>(dur).count();
|
||
|
#if defined(PERF_LOG_MACRO_PRINT_DURATIONS)
|
||
|
std::cout << "Log level requires writing using PERF runtime macro:" << seconds << "us" << std::endl;
|
||
|
#endif
|
||
|
}
|
||
|
}
|
||
|
TEST_CASE("performace test when writing", "[PERF_log_macro]")
|
||
|
{
|
||
|
MyObj obj;
|
||
|
auto null_sink = std::make_shared<spdlog::sinks::null_sink_st>();
|
||
|
auto logger = std::make_shared<spdlog::logger>("null_logger", null_sink);
|
||
|
logger->set_level(spdlog::level::info);
|
||
|
|
||
|
std::size_t loop_count = 1000;
|
||
|
{
|
||
|
auto begin = std::chrono::high_resolution_clock::now();
|
||
|
for (size_t i = 0; i < loop_count; i++)
|
||
|
{
|
||
|
logger->info("custom class with operator<<: {}..", obj);
|
||
|
}
|
||
|
auto end = std::chrono::high_resolution_clock::now();
|
||
|
auto dur = end - begin;
|
||
|
auto seconds = std::chrono::duration_cast<std::chrono::microseconds>(dur).count();
|
||
|
#if defined(PERF_LOG_MACRO_PRINT_DURATIONS)
|
||
|
std::cout << "Log level requires writing using NORMAL interface: " << seconds << "us" << std::endl;
|
||
|
#endif
|
||
|
}
|
||
|
}
|
||
|
|
||
|
|
||
|
TEST_CASE("performace test not writing", "[PERF_log_macro]")
|
||
|
{
|
||
|
MyObj obj;
|
||
|
auto null_sink = std::make_shared<spdlog::sinks::null_sink_st>();
|
||
|
auto logger = std::make_shared<spdlog::logger>("null_logger", null_sink);
|
||
|
logger->set_level(spdlog::level::info);
|
||
|
|
||
|
std::size_t loop_count = 10000;
|
||
|
{
|
||
|
auto begin = std::chrono::high_resolution_clock::now();
|
||
|
for (size_t i = 0; i < loop_count; i++)
|
||
|
{
|
||
|
SPDLOG_PERF_TRACE(logger, "custom class with operator<<: {}..{}", obj, 1234);
|
||
|
}
|
||
|
auto end = std::chrono::high_resolution_clock::now();
|
||
|
auto dur = end - begin;
|
||
|
auto seconds = std::chrono::duration_cast<std::chrono::microseconds>(dur).count();
|
||
|
#if defined(PERF_LOG_MACRO_PRINT_DURATIONS)
|
||
|
std::cout << "Log level does NOT require writing using PERF runtime macro: " << seconds << "us" << std::endl;
|
||
|
#endif
|
||
|
}
|
||
|
{
|
||
|
auto begin = std::chrono::high_resolution_clock::now();
|
||
|
for (size_t i = 0; i < loop_count; i++)
|
||
|
{
|
||
|
logger->trace("custom class with operator<<: {}..{}", obj, 1234);
|
||
|
}
|
||
|
auto end = std::chrono::high_resolution_clock::now();
|
||
|
auto dur = end - begin;
|
||
|
auto seconds = std::chrono::duration_cast<std::chrono::microseconds>(dur).count();
|
||
|
#if defined(PERF_LOG_MACRO_PRINT_DURATIONS)
|
||
|
std::cout << "Log level does NOT require writing using NORMAL interface: " << seconds << "us" << std::endl;
|
||
|
#endif
|
||
|
}
|
||
|
}
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|